The list below provides a summary of the icons displayed on the Operator  
Control Panel. For procedures on how to use these functions, see the Multi-  
media User’s Guide for the Kodak i800 Series Scanners (A-61170).  
These functions can be performed when the scanner is disabled:  
Displays information: including the last image address, meter  
values, scanner serial number.  
Lowers the elevator tray if it is not already in the lowest position.  
Displays the Diagnostics Settings menu.  
Calibrates the scanner.  
Temporarily turns on the transport to help clear a document jam.  
These functions can be performed when the scanner is enabled:  
Increments the image address level.  
Lowers the elevator tray if it is not already in the lowest position.  
Performs the first programmable function.  
Performs the second programmable function.  
Performs the third programmable function.  
When the Diagnostics Settings menu button is selected, these functions are  
available:  
Performs the selected function.  
Moves left to the next selectable item.  
Moves right to the next selectable item.  
Moves up to the next selectable item.  
Moves down to the next selectable item.  
Programmable key functions are assigned at application setup. Check with your  
System Administrator for key assignments. Available functions are:  
·
·
·
·
·
·
No Scanner Functionality (default)  
Scanner End-of-Job  
Terminate Batch  
Omit Multi-feed Detection on Next Document  
Omit Printing on Next Document  
Omit Patch Reading on Next Document  
 
Message Listing  
Following is a list of messages and corrective actions you can take if one of the  
following messages appears on the Operator Control Panel. Most corrective  
actions can be found in the Multi-media User’s Guide for the Kodak i800 Series  
Scanners.  
Calibrate scanner now  
You must calibrate the scanner now.  
Calibration failed  
Perform a controlled power-down sequence; recalibrate the scanner. Be sure  
you are using the correct calibration target.  
Clean imaging guides  
The imaging guides are dirty.  
Clean the S1 sensor  
The S1 (pre-imaging ) sensor is dirty.  
Clean the S2 sensor  
The S2 (post-imaging ) sensor is dirty.  
Control panel button depressed  
A Control Panel button is stuck in the engaged position.  
Document jam  
Clear the paper path.  
Error; Reset Scanner  
Try turning the scanner on and off again. If error persists, call service.  
Image buffer almost full  
Processing will resume when the buffer is less full.  
Image buffer full  
Image data has been lost. Clear the documents and rescan.  
Interlocks are open  
One of the doors is not closed.  
Lamps not stable  
Calibration was attempted before the lamps were warmed up.  
No paper in tray  
Place paper in elevator tray and restart.  
Replace lamps now  
Replace all four lamps now.  
S1 sensor is blocked  
Check for a document jam.  
 
S2 sensor is blocked  
Check for a document jam.  
Self-test failed  
Power down the scanner and try again.  
Settings conflict  
Conflicting or unacceptable settings have been downloaded to the scanner.  
Unable to enable  
Check to be sure all doors are closed.  
Unable to execute command  
You have attempted a command that is not permitted in the current state.  
EASTMAN KODAK COMPANY  
Document Imaging  
343 State Street  
Rochester, NY 14650-1181  
KODAK is a trademark of  
Eastman Kodak Company.  
kodak.com/go/docimaging  
© Eastman Kodak Company, 2001  
A-61171 Printed in USA  
 

Indesit Oven FDE 10 User Manual
JBL Home Theater System L830 User Manual
Jenn Air Cooktop W10204447A User Manual
Jenn Air Microwave Oven JMV8000ADW User Manual
JL Audio Portable Speaker 13W7D15 User Manual
JVC DVD Player XV N330B User Manual
Kaser Network Card YOFUN010 2 User Manual
Kenwood Hot Beverage Maker SJM282 User Manual
Konica Minolta All in One Printer bizhub C300 User Manual
Kramer Electronics Stereo System VS 66H3 User Manual